Level 1 sweep and inspection to the NFPA 211 annual standard - flue, crown, cap, and flashing checked and photographed

Worth knowing

Chimney sweep logs do not sweep chimneys. They loosen some creosote - which then falls where a brush and vacuum still have to collect it.

Styles & brands we work with

Sweep & inspection
Sweep & inspection
Caps & crowns
Caps & crowns
Flue relining
Flue relining
Masonry repair
Masonry repair
Gas fireplace service
Gas fireplace service

Before & after – our own jobs

Before - Recent ProjectBeforeAfter - Recent ProjectAfter
Recent Project
Before - Full RestorationBeforeAfter - Full RestorationAfter
Full Restoration
Before - Complete UpgradeBeforeAfter - Complete UpgradeAfter
Complete Upgrade

DuraFlex Chimney Cap Installation: The Taunton Owner’s Guide

A DuraFlex chimney cap installation in Taunton typically runs $340-$580 for most single-flue setups, including the cap, collar, fasteners, and weather sealing. We stock DuraFlex-compatible caps on every truck, and most replacements are completed in one visit. Homeowners usually discover the problem during the first hard rain of fall, when water starts dripping onto the firebox floor, or when they notice rust stains weeping down the masonry from a cap that’s been slowly failing for two or three seasons.

Call (774) 310-4281

Which DuraFlex Models This Applies To

DuraFlex caps are not one-size-fits-all, and ordering wrong is the most common mistake we correct in Taunton. The critical match points are flue diameter, flue type (round stainless, oval, or square tile), and whether your liner terminates with a top plate or direct-connect collar.

If you still have your DuraFlex paperwork, look for the series stamp: DuraFlex SW for solid-pack stainless, DuraFlex SS for smooth-wall, or DuraFlex 316Ti for the titanium alloy line. The cap must match the liner alloy grade, 304 or 316, or galvanic corrosion accelerates at the joint. We carry both OEM DuraFlex caps and quality aftermarket equivalents from Gelco and Famco that meet the same 304/316 spec. For most Taunton homes built between 1960 and 1990 with original clay flues retrofitted for a wood stove or insert, the DuraFlex 6-inch or 8-inch round with a 13-by-13-inch top plate is the configuration we see most. Measure twice: a cap that’s 1/4 inch undersized will gap in a northeast ice storm, and oversized caps catch wind and torque the flue termination.

Hearthstone Chimney Co. is an independent service provider. We are not affiliated with DuraFlex, though we install their products and stock compatible parts daily.

Signs Your DuraFlex Chimney Cap Installation Is Failing

  • Water dripping onto the firebox floor or rust staining the damper. The cap mesh or lid has corroded through at a seam, or the storm collar has lifted from freeze-thaw cycling. In Taunton, we see this most on caps installed before 2015, when the original 304-grade mesh was thinner than current spec.
  • Birds or squirrels audible in the flue, or nesting debris falling into the fireplace. The mesh sides have pulled away from the frame, or a corner weld has cracked. Once a squirrel gains purchase on a loose cap, they will work the gap wider every season.
  • White efflorescence blooming on exterior brick below the crown. The cap is diverting water onto the crown instead of shedding it clear. This saturates the masonry and, in Taunton’s freeze-thaw climate, spalls the brick face within two winters.
  • The cap is visibly tilted, or you find fasteners on the ground after a storm. The original installer used standard sheet-metal screws instead of stainless expansion anchors rated for masonry. Coastal Massachusetts wind loads will walk a poorly anchored cap loose in three to five years.
  • Smoke backup on mild, humid days. The mesh has clogged with creosote and soot to the point that airflow is restricted. This happens faster with caps that have fine 5/8-inch mesh, common on older DuraFlex models, compared to the current 3/4-inch standard.

Replacement Cost & What’s Included

Component Taunton Price Range
DuraFlex-compatible cap (single flue, 304 or 316 grade) $180-$320
Storm collar and high-temp sealant $45-$75
Labor: remove old cap, inspect flue termination, install and seal new assembly $115-$185
Level-2 camera inspection with photo report Included
Total installed $340-$580

What moves the needle: height of roof access, whether the old cap has seized onto the flue and needs cutting, and if the flue termination itself needs reworking. We photograph everything before we quote. The number on the estimate is the number on the invoice. Every cap installation carries our 90-Day Done Right Promise in writing, no arguing.

DIY or Call Us?

There is a safe middle ground here, and then there is where most homeowners stop.

What you can check from the ground: whether the cap is visibly tilted, whether mesh is missing in sections you can see, and whether the storm collar has lifted. Binoculars help. If you find fasteners on the ground after a storm, the cap is working loose and needs attention before the next wind event.

Where DIY goes wrong: working on a pitched roof above 12 feet without proper tie-off, attempting to remove a seized cap with pry bars that dent the flue, or installing a cap without verifying flue diameter and alloy match. A cap that gaps or overhangs will leak or catch wind, and you will not know until the water damage is done. The flue termination is also your home’s exhaust path for carbon monoxide. Disturb it without knowing how to reseal, and you have created a hazard you cannot see.

We carry DuraFlex-compatible caps, Gelco equivalents, and the Famco line on every truck. Most Taunton replacements are done in a single visit. Call (774) 310-4281 for a free estimate.

FAQs

Need Chimney Cleaning help in Taunton? Licensed & insured · Written inspection reports response · free estimates
Call (774) 310-4281
Local Service Coverage

Request a Free Estimate in Taunton

Tell us what you need - Hearthstone Chimney Co. responds fast. No obligation.

By providing your information above, you accept our Privacy Policy and consent to being contacted by telephone, text message, or email about your request, including by the independent contractors we may refer it to.

Prefer to text? Text Now
Call Now - 24/7 Dispatch